Description
Digital Storage Oscilloscope DCS7500 Series
|
Model |
DCS-7515A |
DCS-7510A |
DCS-7507A |
DCS-4605 |
|
|
Vertical axis |
|||||
|
Sensibility |
2mV/div to 10V/div (1-2-5 steps) |
||||
|
Accuracy |
±(3% ×[Readout] + 0.1div + 1mV) |
||||
|
Bandwidth(-3dB) |
DC(AC)Coupling |
DC(10Hz) to 150MHz |
DC(10Hz) to 100MHz |
DC(10Hz) to 70MHz |
DC(10Hz) to 50MHz |
|
Rise time |
2.3ns max |
3.5ns max |
5ns max |
7.0ns max |
|
|
Input impedance |
1MΩ±2%, Approx.15pF |
||||
|
Maximum input voltage |
300V (DC + AC peak), Installation Category Ⅱ |
||||
|
20MHz bandwidth (-3dB) function |
Available |
||||
|
Trigger |
|||||
|
Sources |
CH1,CH2, LINE, EXT |
||||
|
Modes |
AUTO, NORMAL, SINGLE, TV(Video), Edge, Pulse Width, Forcing |
||||
|
Coupling |
AC, DC, Low/High Frequency rejection, Noise rejection |
||||
|
Trigger sensibility |
0.5div (5mV min.) |
DC to 25MHz |
|||
|
Ext. Trigger sensibility |
1.5div (5mV min.) |
25MHz to 150MHz |
25MHz to 100MHz |
25MHz to 70MHz |
25MHz to 50MHz |
|
Horizontal axis |
|||||
|
Range |
1ns/div to 50s/div, 1-2-5steps (50ms/div to 50s/div at Roll mode) |
||||
|
Modes |
Main, Area magnification, Magnification, Roll, X-Y |
||||
|
Accuracy |
±0.01% |
||||
|
Delay range |
Pre-trigger |
8div max. |
10 div max. |
||
|
Post-trigger |
100div |
1000div |
|||
|
Signal Acquisition System |
|||||
|
Sample rate |
Real-time |
1GS/s max. (1ch) |
250MS/s max. (1ch) |
||
|
Equivalent |
25GSs/s max. |
||||
|
Vertical resolution |
8bits, 25levels/div |
||||
|
Record length |
One mega points max. (2ch), Two mega points max. (1ch) |
4000 points |
|||
|
Acquisition modes |
Normal, Peak Detect, Average |
||||
|
Peak detection |
10ns (500ns/div to 50s/div) |
||||
|
Average |
2, 4, 8, 16, 32, 64, 128, 256 |
||||
|
Cursors and Measurement |
|||||
|
Automatic measurement functions |
Vertical axis |
Peak-to-peak, Max, Min, Amp, High, Low, Average, Rms |
|||
|
Horizontal axis |
Frequency, Period, Rise time, Fall time, |
||||
|
Delaying |
FRR, FRF, FFR, FFF, LRR, LFR, LFR, LFF |
- |
|||
|
Cursors measurement |
Voltage / Time difference between cursors(V, ⊿T, 1/⊿T) |
||||
|
Frequency counter |
Resolution : six digits, Accuracy : ±2%(cannot measure below two Hz) |
||||
|
Interfaces |
|||||
|
USB device port |
Standard equipment, Compliant with USB 1.1 and 2.0 full-speed, |
- |
|||
|
SD card slot |
Standard equipment, Compliant with SD/SDHC (Class 2, 4 and 6), |
||||
|
General |
|||||
|
Power requirements |
100V to 240V AC, 47Hz to 63Hz |
||||
|
Power consumption |
18Watts, 40VA max |
||||
|
Dimensions |
341.5(W)×162.3(H)×159(D)mm |
||||
|
Weight |
Approx. 2.5kg |
||||
|
Accessories |
Probe, AC power cable, |
||||
- Analysis Equipment
- Battery Tester
- Cable Tester
- Calibrator
- Corrosion Tester
- Data Logger & Recorder
- Digital Multimeter
- Electronic Load
- EMC Test Equipment
- Environmental Testing Apparatuses
- Food & Beverage Field Testing Equipment
- Force Meter & Tester
- Industrial Automation
- Industrial Camera
- Industrial Camera
- Industrial Printer
- Industrial Software
- LCR Meter & Impedance Analyzer
- Microscope
- Miscellaneous
- Oscilloscope & Probe
- Power Meter & Power Analyzer
- Power Supply
- Production Equipment
- Safety Tester
- Signal & Function Generator
- Sound Level Meter
- SPC(Statistical Process Control) Solution
- Spectrophoto Meter
- Vibration & Shock Testing System
- Weathering Tester